{"id":1144,"date":"2024-11-06T12:34:10","date_gmt":"2024-11-06T12:34:10","guid":{"rendered":"http:\/\/c4dfed.webshot.in\/?page_id=1144"},"modified":"2024-12-17T11:53:18","modified_gmt":"2024-12-17T11:53:18","slug":"electrical-characterization-system","status":"publish","type":"page","link":"https:\/\/c4dfed.iitmandi.ac.in\/?page_id=1144","title":{"rendered":"Electrical Characterization System \u00a0\u00a0"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"1144\" class=\"elementor elementor-1144\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6ef8b39 e-flex e-con-boxed e-con e-parent\" data-id=\"6ef8b39\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-24fe818 e-con-full e-flex e-con e-child\" data-id=\"24fe818\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6cdb824 elementor-widget elementor-widget-text-editor\" data-id=\"6cdb824\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<h2 style=\"text-align: center;\"><b><\/b><span style=\"color: #000000;\"><strong>Electrical Characterization System\u00a0\u00a0<\/strong><\/span><\/h2><p style=\"text-align: center;\"><span style=\"color: #000000;\"><strong>Manufacturer Name\/Country &#8211; Super Solutions and Keithley Services Co. Ltd\u00a0<\/strong><\/span><\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4665ae1 elementor-widget elementor-widget-image\" data-id=\"4665ae1\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"2560\" height=\"1920\" src=\"https:\/\/c4dfed.iitmandi.ac.in\/wp-content\/uploads\/2024\/11\/Electrical-Characterization-System-scaled.webp\" class=\"attachment-full size-full wp-image-1355\" alt=\"\" srcset=\"https:\/\/c4dfed.iitmandi.ac.in\/wp-content\/uploads\/2024\/11\/Electrical-Characterization-System-scaled.webp 2560w, https:\/\/c4dfed.iitmandi.ac.in\/wp-content\/uploads\/2024\/11\/Electrical-Characterization-System-1024x768.webp 1024w, https:\/\/c4dfed.iitmandi.ac.in\/wp-content\/uploads\/2024\/11\/Electrical-Characterization-System-768x576.webp 768w, https:\/\/c4dfed.iitmandi.ac.in\/wp-content\/uploads\/2024\/11\/Electrical-Characterization-System-600x450.webp 600w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3a75992 elementor-widget elementor-widget-image\" data-id=\"3a75992\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"2560\" height=\"1089\" src=\"https:\/\/c4dfed.iitmandi.ac.in\/wp-content\/uploads\/2024\/12\/20241025_112807-1-scaled.webp\" class=\"attachment-full size-full wp-image-1475\" alt=\"\" srcset=\"https:\/\/c4dfed.iitmandi.ac.in\/wp-content\/uploads\/2024\/12\/20241025_112807-1-scaled.webp 2560w, https:\/\/c4dfed.iitmandi.ac.in\/wp-content\/uploads\/2024\/12\/20241025_112807-1-1024x435.webp 1024w, https:\/\/c4dfed.iitmandi.ac.in\/wp-content\/uploads\/2024\/12\/20241025_112807-1-768x327.webp 768w, https:\/\/c4dfed.iitmandi.ac.in\/wp-content\/uploads\/2024\/12\/20241025_112807-1-600x255.webp 600w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cc0b5cf elementor-widget elementor-widget-image\" data-id=\"cc0b5cf\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"2560\" height=\"1524\" src=\"https:\/\/c4dfed.iitmandi.ac.in\/wp-content\/uploads\/2024\/12\/20241025_113207-1-scaled.webp\" class=\"attachment-full size-full wp-image-1476\" alt=\"\" srcset=\"https:\/\/c4dfed.iitmandi.ac.in\/wp-content\/uploads\/2024\/12\/20241025_113207-1-scaled.webp 2560w, https:\/\/c4dfed.iitmandi.ac.in\/wp-content\/uploads\/2024\/12\/20241025_113207-1-1024x610.webp 1024w, https:\/\/c4dfed.iitmandi.ac.in\/wp-content\/uploads\/2024\/12\/20241025_113207-1-768x457.webp 768w, https:\/\/c4dfed.iitmandi.ac.in\/wp-content\/uploads\/2024\/12\/20241025_113207-1-600x357.webp 600w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f62497b elementor-widget elementor-widget-spacer\" data-id=\"f62497b\" data-element_type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bc9afa1 e-con-full e-flex e-con e-child\" data-id=\"bc9afa1\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-10aad6b elementor-widget elementor-widget-text-editor\" data-id=\"10aad6b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<h4><span style=\"color: #000000;\"><strong>( Lab-3)<\/strong><\/span><\/h4><p><strong><span style=\"color: #000000;\">Product Specification\/Description: \u00a0<\/span><\/strong><\/p><ul><li><span style=\"color: #000000;\">Temperature range Min. to Max. for Thermal Chuck: -40 <sup>o<\/sup>C to 300 <sup>o<\/sup>C<\/span><\/li><li><span style=\"color: #000000;\">Low Noise Probe with Leakage \u2264 5fA for the Application of DC CV, IV, Quasi CV, Very low frequency CV, C-t, I-t\u00a0 Pulsed Measurement etc.<\/span><\/li><li><span style=\"color: #000000;\">Gold Plated Chuck with Diameter \u2265 150 mm<\/span><\/li><li><span style=\"color: #000000;\">DC Channels Triaxial SMU sourcing and measuring range for <strong>Voltage:<\/strong>Voltage Source \u00b15 \u00b5V to \u00b1 200 V,\u00a0 Voltage Measures is \u00b1 0.2 \u00b5Vor low to \u00b1 200 V or high, for <strong>Current: <\/strong>Current \u00a0Source\u00a0 \u00b1 2 fA to \u00b1 1A,\u00a0 Current Measure\u00a0 \u00b1100 aA to \u00b1 1A.<\/span><\/li><li><span style=\"color: #000000;\">High Voltage source meter: Max voltage \u2265 3KV. source or sink up to 3000V @\u00a0 \u2265 4mA or 1500V @\u00a0 \u2265\u00a0 8mA, Voltage resolution is\u00a0 \u2264 200 uV, Current resolution\u00a0 \u2264 10 fA<\/span><\/li><li><span style=\"color: #000000;\">High current source meter Current: &gt;= 20 A (DC) and &gt;= 20 A (Pulse), Max. Voltage &gt; 40 V, Voltage resolution\u00a0 \u2264 1 uV, Minimum Current resolution is \u2264 10 pA<\/span><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Electrical Characterization System\u00a0\u00a0 Manufacturer Name\/Country &#8211; Super Solutions and Keithley Services Co. Ltd\u00a0 ( Lab-3) Product Specification\/Description: \u00a0 Temperature range Min. to Max. for Thermal Chuck: -40 oC to 300 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1144","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/c4dfed.iitmandi.ac.in\/index.php?rest_route=\/wp\/v2\/pages\/1144","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/c4dfed.iitmandi.ac.in\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/c4dfed.iitmandi.ac.in\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/c4dfed.iitmandi.ac.in\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/c4dfed.iitmandi.ac.in\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1144"}],"version-history":[{"count":16,"href":"https:\/\/c4dfed.iitmandi.ac.in\/index.php?rest_route=\/wp\/v2\/pages\/1144\/revisions"}],"predecessor-version":[{"id":1479,"href":"https:\/\/c4dfed.iitmandi.ac.in\/index.php?rest_route=\/wp\/v2\/pages\/1144\/revisions\/1479"}],"wp:attachment":[{"href":"https:\/\/c4dfed.iitmandi.ac.in\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1144"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}