{"id":1087,"date":"2024-11-04T12:01:07","date_gmt":"2024-11-04T12:01:07","guid":{"rendered":"http:\/\/c4dfed.webshot.in\/?page_id=1087"},"modified":"2024-11-08T06:28:11","modified_gmt":"2024-11-08T06:28:11","slug":"field-emission-scanning-electron-microscope-fesem","status":"publish","type":"page","link":"https:\/\/c4dfed.iitmandi.ac.in\/?page_id=1087","title":{"rendered":"Field Emission Scanning Electron Microscope (FESEM)"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"1087\" class=\"elementor elementor-1087\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dee3ae2 e-flex e-con-boxed e-con e-parent\" data-id=\"dee3ae2\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b9d503d elementor-widget elementor-widget-spacer\" data-id=\"b9d503d\" data-element_type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c9bd059 e-flex e-con-boxed e-con e-parent\" data-id=\"c9bd059\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-c6cb8a6 e-con-full e-flex e-con e-child\" data-id=\"c6cb8a6\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-aedf10a elementor-widget elementor-widget-text-editor\" data-id=\"aedf10a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<h2 style=\"text-align: center;\"><b><\/b><span style=\"color: #000000;\"><strong>Field Emission Scanning Electron Microscope (FESEM) \u00a0<\/strong><\/span><\/h2><p style=\"text-align: center;\"><span style=\"color: #000000;\"><strong>Manufacturer Name\/Country &#8211; Carl Zeiss Microscopy GmbH (Germany)<\/strong><\/span><\/p><p style=\"text-align: center;\"><span style=\"color: #000000;\"><strong>Model Name- Gemini 500<\/strong><\/span><\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c0c6dfd elementor-widget elementor-widget-image\" data-id=\"c0c6dfd\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/c4dfed.iitmandi.ac.in\/wp-content\/uploads\/2024\/10\/FE-scaning-electron-microscope.webp\" class=\"attachment-large size-large wp-image-650\" alt=\"\" srcset=\"https:\/\/c4dfed.iitmandi.ac.in\/wp-content\/uploads\/2024\/10\/FE-scaning-electron-microscope.webp 800w, https:\/\/c4dfed.iitmandi.ac.in\/wp-content\/uploads\/2024\/10\/FE-scaning-electron-microscope-768x576.webp 768w, https:\/\/c4dfed.iitmandi.ac.in\/wp-content\/uploads\/2024\/10\/FE-scaning-electron-microscope-600x450.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-96d9cf4 elementor-widget elementor-widget-spacer\" data-id=\"96d9cf4\" data-element_type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8888750 e-con-full e-flex e-con e-child\" data-id=\"8888750\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fbe3594 elementor-widget elementor-widget-text-editor\" data-id=\"fbe3594\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<h4><span style=\"color: #000000;\"><strong>( Lab-1)<\/strong><\/span><\/h4><p><strong><span style=\"color: #000000;\">A) Product Specification\/Description: \u00a0<\/span><\/strong><\/p><ul><li><span style=\"color: #000000;\">Accelerating voltage: 0.02 to 30 kV<\/span><\/li><li><span style=\"color: #000000;\">Resolution: 0.5nm at 15 kV; 0.9 nm at 1 kV; 1.0 nm, at 500V<\/span><\/li><li><span style=\"color: #000000;\">Magnification: Range: 50 \u2013 2.000.00x<\/span><\/li><li><span style=\"color: #000000;\">Work distance 0.1 &#8211; 50 mm<\/span><\/li><li><span style=\"color: #000000;\">Beam current configurations: upto 20 nA<\/span><\/li><li><span style=\"color: #000000;\">5-Axes Motorised Eucentric Stage: Movements X\/Y = 130 mm, Z= 50 mm, T= -4o to 70<sup>o <\/sup>R=360<sup>o <\/sup>continuous<\/span><\/li><li><span style=\"color: #000000;\">High efficiency In-lense SE-detector for high speed SE imaging<\/span><\/li><\/ul><p><span style=\"color: #000000;\"><b><\/b><strong><em><b>B) Micromanipulator System <\/b><\/em><\/strong>\u201c<strong><b>Kleindiek Nanotechnik<\/b><\/strong>\u201d<\/span><\/p><p><span style=\"color: #000000;\">Product Specification\/Description: \u00a0\u00a0<\/span><\/p><ul><li><span style=\"color: #000000;\">Hardware and software module for the Advanced Probing Toolkit for live monitoring of up to four tip signals in order to determine the contact status for each probe. Additionally, the systems also includes the Transistor Test, Tip2Tip, and signal routing components<\/span><\/li><li><span style=\"color: #000000;\">Microgripper (VS5) plug-in for MM3A-EM<\/span><\/li><li><span style=\"color: #000000;\">A force sensor plug-in tool for the MM3A-EM (the system consist of a force sensor holder) and a force measurement tool for up to 8 N ( Consist of a force transducer &amp; control Module)<\/span><\/li><\/ul><p><span style=\"color: #000000;\"><b><\/b><strong><em><b>C) Heating Module<\/b><\/em><\/strong>\u201c<strong><b>Kammrath &amp; Weiss Gmbh\u201d<\/b><\/strong><\/span><\/p><p><span style=\"color: #000000;\">\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0Product Specification\/Description: \u00a0\u00a0<\/span><\/p><ul><li><span style=\"color: #000000;\">5 500 <sup>o<\/sup>C Heating Module with PID Driving Electronics for the SEM, The 500 <sup>0<\/sup>C heating unit is suitable for routine operation. The PID-aided controller allows pre-setting for a certain Experiment temperature, temperature ramps, profiles or cycles. This heating device allows experiments at elevated temperatures with an EBSD-detector.<\/span><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Field Emission Scanning Electron Microscope (FESEM) \u00a0 Manufacturer Name\/Country &#8211; Carl Zeiss Microscopy GmbH (Germany) Model Name- Gemini 500 ( Lab-1) A) Product Specification\/Description: \u00a0 Accelerating voltage: 0.02 to 30 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1087","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/c4dfed.iitmandi.ac.in\/index.php?rest_route=\/wp\/v2\/pages\/1087","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/c4dfed.iitmandi.ac.in\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/c4dfed.iitmandi.ac.in\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/c4dfed.iitmandi.ac.in\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/c4dfed.iitmandi.ac.in\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1087"}],"version-history":[{"count":19,"href":"https:\/\/c4dfed.iitmandi.ac.in\/index.php?rest_route=\/wp\/v2\/pages\/1087\/revisions"}],"predecessor-version":[{"id":1280,"href":"https:\/\/c4dfed.iitmandi.ac.in\/index.php?rest_route=\/wp\/v2\/pages\/1087\/revisions\/1280"}],"wp:attachment":[{"href":"https:\/\/c4dfed.iitmandi.ac.in\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1087"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}